Overview
All optic functions Improved EMI immunity Improved ambient light immunity Improved laser safety level M18 flat plastic with universal mounting Short plastic housing models Available in M18 metal housing Stainless steel housing models Axial or radial optics, cable or connector Standard 4-wire NO-NC NPN or PNP output M12 pigtail models available IO-Link connectivity V1.1 with double channel
Technical Features
Detection properties
| Nominal sensing distance |
30m |
| Sensitivity adjustment |
n/a |
Application
| Function Principle |
Through beam emitter |
| Description |
Tubular M18 - axial optic |
| Optic position |
Radial 90° |
| Functions |
Through beam emitter |
Outputs
| Output type |
n/a |
| Response time |
n/a |
Electrical data
| Operating Voltage |
10…30VDC |
| No-Load supply current |
≤ 35 mA |
| Load current |
≤100mA |
| Leakage current |
≤10μA |
| LED indicators |
green POWER LED |
| Short-circuit protection |
YES |
| Reverse Polarity Protection |
Yes |
| Emission |
LED Infrared |
| Interference to external light |
according to EN 60947-5-2 : 2020 |
| Impulsive Overvoltage Protection |
Yes |
| Insulation resistance |
>20 MΩ 500 Vdc, between electronics and housing |
| Contact resistance |
500 Vac 1 min., between electronics and housing |
Mechanical data
| Dimensions |
Ø18x57 |
| Housing Material |
Plastic - PBT / PMMA |
| Connections |
M12 plug |
| Active Head Material |
PMMA |
| Storage temperature |
- 25°C…+70°C |
| Material |
Plastic - PBT / PC |
| Diameter/Dimension |
M18 |
Test/Approvals
| Approvals |
CE cULus |
| EMC compatibility |
EN 60947-5-2 |
| Shocks and vibrations |
0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6) |
Accessories
| Supplied Accessories |
nuts M18 x 1 |
Generical Data
| Dimensions |
M18x57 |
| Operating Temperature |
- 25°C…+ 55°C (Without freeze) |
| Mechanical Protection |
IP67 |