I.M12,PNP-NO+NC,M12,SchLD,ATEX
Ind.M12,PNP-NO+NC,M12 Plug,Sch-LD
Inductive sensor M12 shielded LD NO+NC/PNP conn. M12, ATEX II 3G Ex nA IIC T5 Gc
Orderable item
-
Description
Technical Features
Detection propertiesNominal sensing distance 4mm Operanting distance 0…3,24mm Standard target 12x12mm FE360 Correction Factor copper: 0,30 / aluminium: 0,35 / brass: 0,40 / stainless steel: 0,75 Thermal drift of Sr < 10% Repeat Accuracy < 5% (UB 24V Ta=23°C ±5°C) Hysteresis 1 … 20% ApplicationDescription M12 standard flush mount Functions Proximity OutputsOutput type PNP Output Function NO + NC Switching frequency 2kHz Electrical dataOperating Voltage 10...30Vdc No-Load supply current ≤ 15mA Load current ≤ 200mA Leakage current ≤ 15μA Output voltage drop ≤ 2V @200mA Max ripple content ≤ 10% LED indicators Yellow LED output state Time delay before availability ≤ 50ms Short-circuit protection Yes Reverse Polarity Protection Yes Impulsive Overvoltage Protection Yes Protection against inductive loads Yes Mechanical dataMounting Shielded Weight 30g Housing Material AISI316L Stainless Steel Connections M12 Plug Active Head Material PPS Tightening torque 25Nm Material AISI316L Stainless Steel Diameter/Dimension M12 Test/ApprovalsApprovals CE cULus ECOLAB DIVERSEY II 3G Ex nA IIC T5 Gc II 3D Ex tc IIIB T85°C Dc EMC compatibility IEC 60947-5-2 Shocks and vibrations Vibration IEC 60068-2-6 / Shock IEC 60068-2-27 AccessoriesSupplied Accessories 2 nuts M12x1 Generical DataDimensions M12 x 1 / L = 64,6mm Operating Temperature -40°C…+80°C (up to 100°C for short exposure during cleaning process) Mechanical Protection IP67