IS-30-C20-S2
IS-30-C20-S2
Inductive Proximity Sensor ø30 standard - non flush 15 mm - namur - M12
Orderable item
-
Description
Overview Standard proximity M4, M5, M8, M12, M18, M30 Double range (i.e. M12 4mm, M18 14mm, M3020mm) Unshielded or shielded models for flush mounting Nickel brass or stainless steel short and longhousing Ecolab and Diversey certifications for industrialdetergents Multi-voltage, Metal face, Weld field immune models NO/NC, NPN or PNP output and programmableversions.
Technical Features
Detection propertiesNominal sensing distance 15mm Operanting distance 0…12,1mm Standard target 45x45mm FE360 Correction Factor copper: 0,4…0,5 / aluminium: 0,4...0,6 / brass: 0,5...0,7 / stainelss steel: 0,7…1,05 Repeat Accuracy < 3% (UB 24V Ta=23°C ±5°C) Hysteresis < 10% ApplicationDescription M30 NAMUR no-flush mount Functions Proximity OutputsOutput type NAMUR Output Function NAMUR Switching frequency 500Hz Response time 1 Electrical dataOperating Voltage 7.7...9Vdc No-Load supply current < 1mA (target absent) Load current < 3mA (target present) Max ripple content ≤ 10% Short-circuit protection Yes Reverse Polarity Protection Yes Emission ≥100kHz Protection against inductive loads Yes Mechanical dataMounting Unshielded Dimensions Ø30x85 Housing Material Nickel-plated brass Connections M12 Plug Active Head Material LCP Tightening torque 40Nm Material Nickel-plated brass Diameter/Dimension M30 Test/ApprovalsApprovals CE cULus II 3G EX nA II T6 II 3D EX tD A22 IP67 T85°C AccessoriesSupplied Accessories 2 nuts M30x1.5 Generical DataDimensions Ø30 / L = 85mm Operating Temperature -25°C…+60°C Mechanical Protection IP67