IS-30-C9-03
IS-30-C9-03
Inductive Proximity Sensor ø30 standard - non flush 15 mm - 2 wire dc no/nc 2 wires - 2m cable
Orderable item
-
Description
Overview Standard proximity M4, M5, M8, M12, M18, M30 Double range (i.e. M12 4mm, M18 14mm, M3020mm) Unshielded or shielded models for flush mounting Nickel brass or stainless steel short and longhousing Ecolab and Diversey certifications for industrialdetergents Multi-voltage, Metal face, Weld field immune models NO/NC, NPN or PNP output and programmableversions.
Technical Features
Detection propertiesNominal sensing distance 15mm Operanting distance 0…12,1mm Standard target 45x45mm FE360 Correction Factor copper: 0,4…0,5 / aluminium: 0,4…0,6 / brass: 0,5…0,7 / stainelss steel: 0,7…1,05 Repeat Accuracy < 3% (UB 24V Ta=23°C ±5°C) Hysteresis < 10% ApplicationDescription M30 standard no-flush mount Functions Proximity OutputsOutput type NPN/PNP Output Function NO/NC Switching frequency 250Hz Response time 2 Electrical dataOperating Voltage 10...30Vdc No-Load supply current < 1,6mA Load current > 1,6 … 100mA Output voltage drop ≤ 6,5V Max ripple content ≤ 10% LED indicators Yellow LED output state Time delay before availability ≤ 50ms Short-circuit protection Yes Reverse Polarity Protection Yes Emission ≥100kHz Protection against inductive loads Yes Mechanical dataMounting Unshielded Dimensions Ø30x81 Housing Material Nickel-plated brass Connections 2m PVC Cable Active Head Material LCP Tightening torque 40Nm Material Nickel-plated brass Diameter/Dimension M30 Test/ApprovalsApprovals CE cULus ECOLAB DIVERSEY AccessoriesSupplied Accessories 2 nuts M30x1.5 Generical DataDimensions Ø30 / L = 81mm Operating Temperature -25°C…+70°C Mechanical Protection IP67