• Trusted Global Partner
  • Fast delivery
  • Phone +46 40385000

M18,2 wires DC-NO,Cabl,Sch-STD

Ind.M18,2 wires DC-NO,Cable,Sch-STD
Inductive sensor M18 shielded NO cable 5m axial

Article no.: AK1/A0-1A86
Orderable item
  • Description

    Technical Features

    Detection properties
    Nominal sensing distance 5mm
    Operanting distance 0…4,05mm
    Standard target 18x18mm FE360
    Correction Factor copper: 0,40 / aluminium: 0,48 / brass: 0,50 / stainless steel: 0,86
    Thermal drift of Sr < 10%
    Repeat Accuracy < 5% (UB 24V Ta=23°C ±5°C)
    Hysteresis 1 … 20%
    Application
    Description M18 standard flush mount
    Functions Proximity
    Outputs
    Output type NPN/PNP
    Output Function NO
    Switching frequency 300Hz
    Electrical data
    Operating Voltage 10...30Vdc
    No-Load supply current ≤ 20mA
    Load current 3…100mA
    Leakage current ≤ 0,≤ 8mA
    Output voltage drop ≤ 2,8V @100mA
    Max ripple content ≤ 10%
    LED indicators Yellow LED output state
    Time delay before availability ≤ 50ms
    Short-circuit protection Yes
    Reverse Polarity Protection Yes
    Impulsive Overvoltage Protection Yes
    Protection against inductive loads Yes
    Mechanical data
    Mounting Shielded
    Housing Material Nickel-plated brass
    Connections 5m PVC Cable
    Active Head Material PBT
    Tightening torque 25Nm
    Material Nickel-plated brass
    Diameter/Dimension M18
    Test/Approvals
    Approvals CE UR
    EMC compatibility IEC 60947-5-2
    Shocks and vibrations Vibration IEC 60068-2-6 / Shock IEC 60068-2-27
    Accessories
    Supplied Accessories 2 nuts M18x1
    Generical Data
    Dimensions M18 x 1 / L = 50mm
    Operating Temperature -25°C…+70°C
    Mechanical Protection IP67
  • Files